Commit graph

2 commits

Author SHA1 Message Date
6d8a5d9ad7 Review 1.5: a Windows server that hangs no longer holds up the agent; reads are bounded and backed off
Deadlines
- Event log over RPC (MS-EVEN6): the whole read has a deadline (OperationTimeout per log);
  the token cancels the EventLogSession's operations and is checked before each
  FormatDescription, and the agent stops waiting even if the native call ignores it.
  Reported as ServerAccessProblem.Timeout ("svarede ikke i tide over hændelsesloggens
  protokol (RPC) inden for N sekunder").
- Every CIM call runs on the thread pool and is awaited with the caller's token; a call
  that ignores cancellation is abandoned and the CIM session is closed once it returns.
- Each server cycle has a deadline (new SQLInsight:Servers:CycleTimeout, default 5 min,
  1-30 min, at least 2 x OperationTimeout): the areas not read by then are "ikke målbar"
  ("Serveren svarede ikke inden for N minutter, så indsamlingen blev afbrudt; …"),
  logged once, and the slot is freed.
- Scheduled tasks: run information is read within a time budget (CycleTimeout / 3); the
  rest keep their state without the last run, and the coverage note says so.
- "Test server" has an overall deadline (WindowsServerTester, default 2 min); areas not
  done in time are reported as not answered, so the result is always stored.

Backoff and memory
- A server that does not answer (Unreachable/Timeout, or a timed-out cycle) is backed
  off 1, 2, 5, 10, then 15 minutes, reset when it answers.
- Protocol Auto: the protocol that worked (e.g. DCOM after WS-Man was refused, also for
  access denied) is tried first for an hour, then WS-Man is tried again; a server whose
  event log RPC failed is read over CIM for an hour.
- Over WS-Man with read-only WinRM rights Task Scheduler's GetInfoByName is denied: with
  Auto the tasks are read over DCOM instead (remembered for the server); with WSMan forced
  the reason says to choose Auto or DCOM. The advice "winrm configSDDL default" (broader
  WinRM rights) is gone; texts follow the grant script (-WinRM read right,
  -EnableFirewall -AgentAddress), not Remote Management Users.

Events
- Each log continues from its own mark (ServerEventSnapshot.LogReadUntil, a small additive
  field in Core): a truncated System log no longer loses the events between its last
  read event and the newest Application event.
- CIM fallback: Win32_NTLogEvent is streamed and only the oldest max per log are kept
  (memory bounded, deterministic order), consistent with the RPC read and the coverage
  text, which now names the logs that had more.

Other
- CimInstances (and method results) are mapped to SQLInsight's types and disposed at once.
- Options are clamped when bound (ServerOptions/SyntheticCheckOptions.Normalize):
  OperationTimeout 5 s-5 min, MaxEventsPerCollection 10-10000, MaxWatched 1-200,
  MaxParallelServers/Checks 1-32, retention days >= 1, ForecastHistoryDays 1-365,
  FailuresBeforeFinding/SlowRunsBeforeFinding 1-99.
- Shutdown: the timer's cancellation is caught, running cycles are awaited before the
  throttle is disposed; a cycle's time is taken when it gets its slot; a TaskCanceledException
  that is not shutdown no longer ends the service.
- Retention maintenance also runs (hourly) when SQLInsight:Servers:Enabled is false but
  synthetic checks are on.
- LocalCimTests run alone (collection without parallelization), share one warmed-up
  session, use the same 2 min operation timeout and a 5 min deadline per test, a smaller
  workload, and report timings in assertion messages.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-02 16:02:17 +02:00
7082b278e3 Collection: Windows servers over CIM (WS-Man, DCOM fallback) and synthetic check runners
New project SQLInsight.Servers:
- CimWindowsServerSource (Microsoft.Management.Infrastructure, the API behind
  Get-CimInstance): WS-Man first, DCOM if that fails, a local session for the
  agent's own computer, as the agent's identity. Only SELECT queries (CimQueries)
  and Task Scheduler's read-only GetInfo. CPU and paging from raw counters, disks
  (Win32_Volume, Win32_LogicalDisk fallback), services, scheduled tasks, and the
  System/Application logs through the Event Log service (MS-EVEN6, XPath filter on
  the server) with Win32_NTLogEvent as fallback.
- ServerErrors: access denied, missing namespace, RPC/WinRM unreachable and
  timeouts become "ikke målbar" reasons that name the missing right and the grant
  script; never local administrator.
- WindowsServerTester: tries every area once for the web UI's test.
- SyntheticCheckRunner: TCP, HTTP(S) with expected status/text and TLS certificate
  expiry (also for refused certificates), SQL login + read-only query (re-validated,
  in a transaction that is always rolled back), DNS, and the Dynamics AX logon:
  AOS port, then a logon through the .NET Business Connector in a separate Windows
  PowerShell process with a timeout when it is installed; otherwise the result
  says clearly that only the port was tested.

Tests: error mapping, queries, AX command/parsing, runners against local TCP and
HTTP(S) servers with a self-signed certificate, the CIM source against this
computer, and the SQL check against the test instance.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-02 14:58:18 +02:00