Commit graph

3 commits

Author SHA1 Message Date
66ed4e11b3 Review 1.4: AX 3.0/4.0 local times in the AX time zone, with its DST rules
Axapta 3.0 and AX 4.0 store batch and cleanup times as a local date plus
seconds. They were turned into UTC with the SQL Server's offset at collection
time, so every time from the other side of a DST change was an hour off (a job
planned 01:50 CET on the spring night looked 70 minutes late at 03:00 CEST),
and a SQL Server running UTC behind a CET AOS shifted every time.

AxLocalTime converts with the rules of the AX time zone on that date:
SQLInsight:DynamicsAx:LocalTimeZone (Windows or IANA id), else the agent's own
zone when its offset matches the SQL Server's, else the server's offset (to the
nearest quarter hour) with a Danish data note. The skipped spring hour and the
repeated autumn hour get standard time (deterministic, never throws, never a
false "late"); seconds outside 0..86400 are unknown and 86400 is midnight. The
AX 3.0 cleanup time is local by version, also when LATESTCLEANTIME is missing.
AX 2009+ UTC times are untouched. Also: remaining numbers cannot overflow for
HIGHEST = Int64.MaxValue, and run keys use the invariant culture.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-02 14:19:17 +02:00
fdaa7e76bf Review 1.4: the AX batch history watermark no longer gets stuck
After the first read, BATCHJOBHISTORY was read from the watermark minus an
overlap of 2000 RecIds with TOP (1000), oldest first. From AX 4.0 RecIds are
handed out per table and are dense, so once 1000 rows existed in the overlap
every read returned the same old rows: the watermark never moved and new runs
were never read again (every AX 2009/2012 installation with more than ~1000
history rows). The read after the watermark now takes the overlap plus 1000
rows (TOP (3000)), so at least 1000 new runs are read each time. Test with
20,000 dense RecIds.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-02 14:15:49 +02:00
4ebae4efe6 Dynamics AX core: central detector, per-version schema adapters, read-access GRANT
One place recognises AX (version 3.0/4.0/2009/2012/2012 R2/F&O, schema owner,
model store) from metadata only. Per-version adapters hold all table/column
knowledge, check every column in sys.columns before use and degrade to
'ikke målbar' with the exact column or the exact GRANT text. Only AX 3.0 is
verified against a real customer schema; 2009/2012 are written from
Microsoft's documented schema (docs/dynamics-ax/*.documented.tsv, replaced
by a real export when one is dropped in). grant-dynamics-ax-read.sql is
version- and schema-aware (bmssa) and covers exactly the adapters' tables.

Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
2026-10-02 13:52:58 +02:00